WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property

damage, personal injury or loss of life. Failure to follow all instructions in the proper order

can cause personal injury or death. Read and understand all instructions, including all

those contained in component manufacturers manuals which are provided with the

appliance before installing, starting-up, operating, maintaining or servicing this appliance.

Keep this manual and literature in legible condition and posted near appliance for reference

by owner and service technician.

This boiler requires regular maintenance and service to operate safely. Follow the

instructions contained in this manual. Installation, maintenance, and service must be

performed only by an experienced, skilled and knowledgeable installer or service agency.

All heating systems should be designed by competent contractors and only persons

knowledgeable in the layout and installation of hydronic heating systems should attempt

installation of any boiler. It is the responsibility of the installing contractor to see that all

controls are correctly installed and are operating properly when the installation is

completed. Installation is not complete unless a pressure relief valve is installed into the

specified tapping located at the rear of appliance - See Section III of this manual for details.

This boiler is suitable for installation on combustible flooring. Do not install boiler on

carpeting. Do not operate on floors where heat affected material is below.
Do not tamper with or alter the boiler or controls. Retain your contractor or a competent

serviceman to assure that the unit is properly adjusted and maintained.

Clean boiler at least once a year - preferably at the start of the heating season to remove

soot and scale. The inside of combustion chamber should also be cleaned and inspected

at the same time.

Have Burner and Controls checked at least once a year or as may be necessitated.

Do not operate unit with jumpered or absent controls or safety devices.

Do not operate unit if any control, switch, component, or device has been subject to water.
Return water cannot be lower than 135°F for prolonged periods of time. Operation under

these conditions will result in sustained condensing within the combustion chamber and

potentially reduce boiler longevity.

In addition, the return water cannot be introduced into the boiler if it is more than 40°F less

than the idle boiler temperature. Continued operation under these conditions may result in

premature boiler failure through thermal shock.

Example: A boiler that has been idle for some time since the last heat demand cycle may

have it's boiler water temperature reduced to 150°F. The return temperature from the next

zone activation cannot be less than 110°F.

If the above conditions exist, an RTC system must be installed to protect the boiler from

sustained condensing operation and thermal shock.