Danger – Crown Boiler 24-07 User Manual

Page 54

Advertising
background image

54

2. CLEAN THE BOILER FLUEWAYS

a. Remove the jacket left side panels.
b. Loosen nuts securing the flue cleanout plates

and remove the plates. The insulation should

be removed with the plates taking care not to

damage the insulation.

c. Using a 1¼” diameter wire or fibre bristle brush

(36” handle) clean the flueways. Start at the top

of each flueway opening and work down the pin

rows using two or three horizontal strokes per

row for best results.

3. CLEAN TOP OF BOILER SECTIONS
Remove the jacket top panel. Remove the top flue

canopy cover or outlet assembly. Use a flashlight to

inspect the upper portion of the flueways and top of

castings for soot and debris. Heavy accumulations

over 1/16” thick must be removed. Remove the

canopy being careful not to damage the cerafelt

strips. Brush and vacuum the upper flueways and

tops of castings.

4. CLEAN THE FIREBOX

a. Disconnect fuel line(s) and remove burner and

burner mounting plate.

A.

GENERAL — Inspection should be conducted

annually. Service as frequently as specified in

paragraphs below. While service or maintenance is

being done, electrical power to the boiler must be “off”.

B.

CLEAN THE BOILER HEATING

SURFACES & FLUE at least once each year,

preferably at the end of the heating season.

1. CLEAN THE VENT SYSTEM — Vent system

should be checked annually for:

a. Obstructions.
b. Accumulations of soot.
c. Deterioration of vent pipe or vent accessories

due to condensation or other reasons.

d. Proper support — no sags, particularly in

horizontal runs.

e. Tightness of joints.
f. Remove the smoke pipe. Remove all

accumulations of soot with wire brush and

vacuum. Remove all obstructions. Replace all

deteriorated parts and support properly. Seal all

joints.

SECTION V - SERVICE INSTRUCTIONS

WARNING

This boiler must only be serviced and repaired by skilled and experienced service

technicians.

If any controls are replaced, they must be replaced with identical models.
Read, understand and follow all the instructions and warnings contained in all the sections

of this manual.
If any electrical wires are disconnected during service, clearly label the wires and assure

that the wires are reconnected properly.

NEVER operate boiler without all sight glasses and brackets in place and securely fastened

and sealed. Very HOT combustion gas may cause burn injury.
Read, understand and follow all the instructions and warnings contained in ALL of the

component instruction manuals.

Assure that all safety and operating controls and components are operating properly before

placing the boiler back in service.

DANGER

This boiler uses flammable gas, high voltage electricity, moving parts, and very hot water

under high pressure. Assure that all gas and electric power supplies are off and that the

water temperature is cool before attempting any disassembly or service.

More than one gas shut-off valve and electrical disconnect switch are used on the boiler.

Assure that all gas valves and electrical disconnect switches are off before attempting any

disassembly or service.
Do not attempt any service work if gas is present in the air in the vicinity of the boiler.

Never modify, remove or tamper with any control device.