A7. Indirect

Application Only with RTC – NO Building Heat (MECHANICAL)

NOTES:

1)

Install the boiler as indicated above for systems where the boiler return temperatures may be less than 135F and heating DHW with an indirect water heater or heat exchanger

.

2)

The boiler circulator must be sized using the sizing charts found in

Appendix B.

3)

The return sensor

, S1, shall be installed at the return of the boiler

.

The boiler circulator may be located anywhere within the recirculation loop.

4)

The balancing valve in the boiler return line, V1, may be necessary in low head by-pass loop applications.

5)

The indirect heater aquastat (A1) is a normally closed switch. Circuit breaks on temperature rise.

6)

Expansion tanks, air scoops and other components left out for clarity

.

7)

Observe all applicable plumbing and electrical codes.

This diagram is for reference only

. The installer or designer is responsible for the proper selection and design of the

system.