Operational check, Programming instructions, Kp series keypad mortise lock 7 – SARGENT Keypad Exit Devices User Manual

Page 18

Advertising
background image

18 1-800-810-WIRE • www.sargentlock.com • A7373C

Copyright © 2014, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

03/31/14

KP Series

Keypad Mortise Lock

7

Operational Check

• Place key into cylinder and rotate key.
• The key will retract the latchbolt.
• If the deadbolt is thrown, the key will retract both the deadbolt and the latchbolt.
• Inside handle lever retracts latchbolt and (if provided).
• Enter 1234

* to unlock outside lever handle and retract latchbolt and deadbolt (if provided).

N

O

P

Q

R

S

T

U

V

M

G

@

Latchbolt

Deadbolt

(KP8276/KP8278)

Outside of Door

Inside of Door

• Key should rotate freely. There should be no friction against lock case, wire harness or any

other obstructions.

• Refer to Step 7 if harness friction exists.
• Rotate cylinder further into lock case to eliminate lockbody obstruction.

Programming Instructions

The KP Keypad Lock can support 100 users. Each user is assigned a User Number in addition to

the code used for entry.
Example:

USER TYPE

USER NUMBER

USER CODE

(2-6 DIGITS)

Master

Emergency

Supervisor

01

02

03

1 2 3 4

2 2 2 2 2

3 0 3 0 3 0

Standard

04-97

2 6 5

Special Factory

10 Sec. Time Preset

98

99

1 3 6 8

8

Advertising
This manual is related to the following products: