KP Series

Keypad Mortise Lock

This Keypad Mortise Lock has 99 User Codes available for programming purposes.

• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is

also used for programming and will override the deadbolt

*

. Users are deleted through the Master Programming

Code only.
• The Emergency Code is always User “02”. The Emergency Code will override the deadbolt

*

in the mortise lock

and has an unlock time of 10 seconds.
• The Supervisory Code is always User “03”. The Supervisory Code allows temporary lockout of selected users,

changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes.
• The first User Code will be User “04” or higher. User numbers do not have to be used or entered sequentially.
• User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person

extra time which would not be required by other users.

To Begin Programming:

The Keypad Mortise Lock is preset at the factory with Master Code “1234”. Entering “1234

*” will unlock the

lock allowing the lever handle to retract the latchbolt.

Initial Set-Up Procedures:

• The following are typical procedures to follow when setting up your KP Series Keypad.
• If a mistake is made during any of procedures, depress the “

*” several times until the yellow LED goes out.

• If no keystroke is made in a 30-sec time frame the programming up to that point will default and you will

have to start over.

If after the last “

*

” is depressed, the yellow LED does not go out, depress “

*

” once more.

Change Master Code:

• 1234

* (Yellow LED Begins to Blink Slowly) This example uses the Factory Default Master Code

• 50# 1# 01# New Master Code

* (Yellow LED Blinks Quickly)

• New Master Code

* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)

To Enter the Emergency Code: (Unlock Duration is Factory Set at 10 Sec)

• Master Code

* (Yellow LED Begins to Blink Slowly)

• 50# 1# 02# Emergency Code

* (Yellow LED Blinks Quickly)

• Emergency Code

* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)

To Enter the Supervisory Code:
• Master Code

* (Yellow LED Begins to Blink Slowly)

• 50# 1# 03# Supervisory Code

* (Yellow LED Blinks Quickly)

• Supervisory Code

* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)

To Enter a User Code:
• Supervisory or Master Code

* (Yellow LED Begins to Blink Slowly)

• 50# 1# User Number (04-97)# User Code

* (Yellow LED Blinks Quickly)

• User Code

* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)

*NOTE: PHR-prefix locks will not allow Emergency or Master Code users entry when deadbolt is thrown.
Entry (with deadbolt thrown) is through key cylinder override only.

All of the following procedures start with 99#.