General Description

The SARGENT KP Series Mortise Lock is designed for areas which require stand alone

authorized entry. It is a self-contained microprocessor-controlled keypad with non-volatile memory.
The keypad holds a total of 100 different user codes. User codes

01, 02 and 03 are utilized for

Master Code, Emergency Code and Supervisory Code, respectively.
This motorized 8200 mortise lock is operated by four (4) “C”

alkaline batteries.

SARGENT mortise locks are designed with quality components to provide high security,

performance and durability.

Specifications

• Latchbolt - Stainless Steel
• Deadbolt - Stainless Steel
• Guardbolt - Stainless Steel, non handed
• Handed - Easily field reversible without

disassembling the lock body

• Case - 12 gauge heavy duty wrought steel
• Outside lever controlled by keypad
• Inside lever retracts latchbolt and deadbolt

3

2

Features

4

• Non-volatile memory
• Motor driven, battery operated mortise lock
• Battery operated with 4 (each) “C” Alkaline
• Low battery alert – 4 chirps after code entry
• Option Code available to sound horn every

time keypad is pressed

• External remote “request to enter” connector

requires wire harness (52-2071)

• External battery input connector included to

power unit in event of battery failure

• All programming done at keypad
• Deadbolt switch inside mortise lock allows

Emergency Code and Master Code users to

gain entry when deadbolt is thrown

*

• Operates utilizing any two to six digits

per code. Digits may be repeated and

codes may start with zero

• Adjustable unlock time
• Entry of three wrong User Codes

disables all codes for ten seconds.

Green LED flashes.

• Piezo horn can be heard with each

keystroke or turned off by Master or

Supervisory Code

• Last 15 transactions can be output to

printer via Data Transfer Device (DTD)

• 100 users total: one Master Code, one

Emergency Code, one Supervisory

Code, with the rest being standard

codes, passage codes, or one time

only codes

• Locks furnished for 1 3/4” doors. Can

be furnished for other door sizes upon

request. (Consult factory)

• UL Listed (3 hr.)
• Accepts size 41(standard) and 42

(removable core) SARGENT mortise

cylinders (KP8276 and KP8278)

• Key retracts latchbolt (KP8276 and

KP8278)

* PHR-prefix locks will not allow Emergency or Master Code users entry when deadbolt is thrown.