Kp series keypad mortise lock – SARGENT Keypad Exit Devices User Manual

Page 21

Advertising
background image

03/31/14

1-800-810-WIRE • www.sargentlock.com • A7373C 21

Copyright © 2014, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

KP Series

Keypad Mortise Lock

All of the following procedures start with 99# (continued).

If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.

To Interrogate Transaction Log:

• Supervisory or Master Code

* (Yellow LED Begins to Blink Slowly)

• 70# 0# 0# (Yellow LED Blinks Slowly)

* (Yellow LED Begins to Blink Quickly)

* (Yellow LED Goes Out)

For additional information, see “Transaction Log”.

Hold an infrared printer up to the red
infrared LED (as shown). A Data Transfer

Device (DTD) can be used to download
information from the keypad to a printout.

Illustration

To LED

location

DataTransfer Device

(DTD)

Note: Seq. # 1 is the

programming request

to output the entries.

Sequence numbers 2-6

are the actual entries.

Door # 5666

Seq

User

Trans

1

001

003

2

003

001

3

003

001

4

020

001

5

003

001

Door Number

Transaction

Number

User Number

Transaction

Type

To Reset / Clear Transaction Log
• Master Code

* (Yellow LED Begins to Blink Slowly)

• 76# 00000# 00000# (Yellow LED Blinks Slowly)

* (Yellow LED Begins to Blink Quickly)

* (Yellow LED Goes Out)

To Delete a User Number:
• Master Code

* (Yellow LED Begins to Blink Slowly)

• User Number# (Yellow LED Blinks Slowly)

* (Yellow LED Begins to Blink Quickly)

* (Yellow LED Blinks Slowly)

* (Yellow LED Goes Out)

To Disable / Enable a User Number:

• Supervisory or Master Code

* (Yellow LED Begins to Blink Slowly)

• 56# 0# = Enable, 1# = Disable User Number# (04-99) (Yellow LED Blinks Slowly)

* (Yellow LED Begins to Blink Quickly)

* (Yellow LED Blinks Slowly)

* (Yellow LED Goes Out)

To Set Unlock Time:
• Master Code

* (Yellow LED Begins to Blink Slowly)

• 85# Time Duration# (01-99 Sec) 0# (Yellow LED Blinks Slowly)

* (Yellow LED Begins to Blink Quickly)

* (Yellow LED Blinks Slowly)

* (Yellow LED Goes Out)

Note:

The Unlock Time is Adjustable for Momentary Operation. A 5 second unlock time is recommended to extend battery life.

Once the unlock time is entered, it is the same for ALL users except 02, 98 and 99 which are factory set for 10 seconds.