Keypad Programming Instructions

Enter a Card, Tag and Fob User

99# Master Code*

Yellow LED blinks

50#

Yellow LED blinks

(Select only one number below, end it with a #, ie 4#)
0= Passage Code; 1= Standard User; 3= Lockout Code; 4= Extended Unlock User; 5= One Time User; 7= Emergency
Code; 8= Communications Enable; 9= Panic User

(Yellow LED blinks)

(User Number 03-2000)#

Yellow LED blinks

*

Yellow LED blinks Quickly

*

Yellow LED blinks Slowly (if Solid See Note)

Present Card, Tag or Fob

Beep / Yellow LED blinks

*

Yellow LED blinks Slowly

*

Yellow LED Goes Out

Enter a User Code + Card, Tag, and Fob

99# Master Code*

Yellow LED blinks

50# 1# (User Number 03-2000)#

Yellow LED blinks

User Code (1-6 digits)*

Yellow LED blinks quickly

User Code (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

Present Card, Tag or Fob

BEEP / Yellow LED blinks

*

Yellow LED blinks slowly

*

Yellow LED goes out

Reset Master Code back to factory default (1234) and retain all other User codes

99# Master Code*

Yellow LED blinks

40# 00000# 00000#

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks very fast for 10 sec., then slow

*

Yellow LED goes out

Note: The factory default Master Code (1234) must be changed (i.e., “Forced Change”) prior to adding
any other users.

To Clear the Entire Memory (Master Code defaults to 1234)

99# Master Code*

Yellow LED blinks

46# 00000# 00000#

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks very fast for 10 sec., then slow

*

Yellow LED goes out

This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*
Sets Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be required to clear the
memory. Call 1-800-810-9473.
Note: The factory default Master Code (1234) must be changed (i.e., “Forced Change”) prior to adding any
other users.

Turn OFF Audio Beep verification on every Key Depression

99# Master Code*

Yellow LED blinks

30# 0# 0# (Off) (1# = On)

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Turn ON Yellow LED verification on every Key Depression

99# Master Code*

Yellow LED blinks

30# 1# 1# (On) (0# = Off)

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

16

© SARGENT Manufacturing Company 2006, 2007

For installation assistance, contact SARGENT at 800-810-WIRE (9473)