Profile Series v.G1.5 Mortise Dorm Lock

A self-contained microprocessor-controlled keypad with non-volatile memory, the SARGENT Profile v.G1.5 Dorm
Mortise Lock is designed to prevent residents from being locked out of their rooms. The resident presents a
proximity card and/or pin code, which works as a toggle to unlock (overriding the deadbolt if thrown) or relock the
outside lever. When entering a room, the deadbolt locks the outside lever. When exiting the room, retracting the
deadbolt unlocks the outside lever.

If the outside lever is locked and the deadbolt is not thrown, rotating the inside lever will unlock the outside lever
(via the lockbody’s inside monitor switch).

The resident must present their prox card and/or pin code to relock the door.

The keypad (G1-PK, G1-PA only) will hold a total of 2000 different user codes. User codes “01” & “02” are utilized
for Master and Supervisory Codes, respectively.

This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality
components to provide high security, performance and durability.

General Description

2

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced TV technician for help

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme avec la norme NMB-003 du Canada.

Warning

1

Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.

Warning

!

To comply with “Fire Listed” doors the batteries must be replaced with alkaline batteries only.

Specifications

• Latch - Stainless steel

• Deadbolt - Stainless steel

• Guardbolt - Stainless steel, non handed

• Handed - Easily field reversible without

disassembling the lock body

• Case - 12 gauge heavy duty wrought steel

• Outside lever controlled by any combination of

keypad or proximity

• Inside lever retracts latch and deadbolt signalling the

outside lever to unlock

• Locks furnished for 1-3/4" doors. Can be furnished

for other door sizes upon request. Consult factory.

• U.L. Listed (3 hr.)