Profile Series v.G1.5 Mortise Dorm Lock
6.3 – Lockbody Installation
6.4 – Fire Stop Plate Installation
- Tuck the two 2 Pin connectors into the inside cylinder hole of the lockbody first. Then, feed Motor Harness
with 6 Pin connector into the mortise pocket followed by the lockbody.
- While sliding the lockbody into the mortise pocket, feed the Motor Harness with the 6 Pin connector
through the inside cylinder hole followed by the two 2 Pin Connectors.
Outside of
door
CL Of 1-1/2" Dia.
(2) Self tapping screws
#8 x 1/2" long for wood
& metal doors
(2) 1/8" Dia. holes required
7"
7"
8
8
1"
1"
2
2
Slot
1
1
Fire stop plate
NOTE: Required for 12- fire rated doors only
MUST feed
Connectors
& Wires thru
non-cylinder
side
Inside of
door
(2) #12-24 x 1/2" long
flat head screw
for metal doors
Hold loosely in place with (2) lockbody screws
DO NOT COMPLETELY TIGHTEN SCREWS AT THIS TIME
Inside Cylinder
Hole
Two (2) Pin
Connectors
tucked into
inside cylinder
6
© SARGENT Manufacturing Company 2006, 2007