Profile Series v.G1.5 Mortise Dorm Lock

6.3 – Lockbody Installation

6.4 – Fire Stop Plate Installation

- Tuck the two 2 Pin connectors into the inside cylinder hole of the lockbody first. Then, feed Motor Harness

with 6 Pin connector into the mortise pocket followed by the lockbody.

- While sliding the lockbody into the mortise pocket, feed the Motor Harness with the 6 Pin connector

through the inside cylinder hole followed by the two 2 Pin Connectors.

Outside of

door

CL Of 1-1/2" Dia.

(2) Self tapping screws
#8 x 1/2" long for wood
& metal doors

(2) 1/8" Dia. holes required

7"

7"
8

8

1"

1"
2

2

Slot

1

1

Fire stop plate

NOTE: Required for 12- fire rated doors only

MUST feed
Connectors
& Wires thru
non-cylinder
side

Inside of

door

(2) #12-24 x 1/2" long
flat head screw
for metal doors

Hold loosely in place with (2) lockbody screws
DO NOT COMPLETELY TIGHTEN SCREWS AT THIS TIME

Inside Cylinder
Hole

Two (2) Pin
Connectors
tucked into
inside cylinder

6