Profile Series v.G1.5/LK Mortise Lock

Step #7 – Inside Escutcheon Wire Connections

Images are shown without gasket.
If gasket is necessary, refer to Step #5.
Before the controller is attached

to the door:

1. Attach the reader assembly

ribbon cable into the back

of the controller assembly

(side that faces towards

the door when mounted

(Fig. 7A).

2. Attach the ground wire to

the bottom of the controller

assembly (E1, Fig. 7A).

3. Connect the cable from

the cylindrical lock to

the bottom of the controller

assembly (TB1, Fig. 7B).

If

Hardwiring is required,

go to “Hardwire Wiring Options”

on page 14.

4. Place extra wire inside door hole

and/or outside escutcheon,

being careful not to pinch wires.

Connectors go on only one way.
Do not offset connectors, and make

sure they are completely seated.

Ground

Wire

Fig. 7A

1

Outside

Escutcheon

2

Ground
Wire

Reader
Cable

Reader
Ribbon

Cable

1

Inside

Escutcheon

(Back)

3

TB1

Inside of Door

3

2

Lock

Cable

Red

Black

Red

Black

Green

Green

With

Deadbolt

Without

Deadbolt

Fig. 7B

Lock Body

Wire Harness

Lock Body

Wire Harness

TB1

Ground

Motor

Connector

Remote Power

REX Connector

TB1

TB1

3