Profile Series v.G1.5/LK Mortise Lock

Step #6 – Install Outside Escutcheon and Lever Assembly

1A.

For 12- fire rated doors: Feed ribbon cable with connector and ground wire from

outside of door through weather seal gasket and fire stop plate (Fig. 6A).
Note: Install ribbon cable with cable exiting down
1B.

For non-12- fire rated doors: Feed ribbon cable with connector and ground

wire from outside of door through weather seal gasket (if used)

and weather conduit (not shown).
Note: Install ribbon cable with cable exiting down, orienting with side

marked ‘TOP’ facing up.

2. With outside lever horizontal, locate the outside escutcheon on the door,

while directing the mounting posts through the door and lock body (Fig. 6B).

3. Make certain the lever spindle is properly engaged in lock.
4. On the inside of the door, insert spindle into square hole of mortise lock.
5. Slide inside adapter and plate assembly over spindle

and loosely secure with 2 through

bolt screws (#8-32 x 5/8”).

Note: For 8276 and 8278,

loosely thread cylinder through

escutcheon and into the lock

body before tightening the

lock case screws and

escutcheon through-bolts.

Fig. 5B

Step #5 – Install Weatherseal Gasket (Exterior Doors)

1. Carefully remove the backing from the gasket.
2. Apply gasket to escutcheon:

• Starting in one place, press the adhesive side

of the gasket firmly against the escutcheon.

• Work around the escutcheon, pressing the sticky side

of the gasket firmly against the escutcheon edge.

• The gasket should be aligned so that all edges

of the escutcheon are covered.

3. Attach escutcheon to the door.

Note: The 43 cylinder may be used with or without a gasket.

Fig. 5A