Profile Series v.G1.5/LK Mortise Lock

1. Insert lock body into mortised cutout (Fig. 3A).
2. Hold lock body loosely in place with (2) lock

body screws.

Note: Do not completely tighten screws at this time.

Step #3 – Install Lock Body

Fire-rated doors require a fire stop plate on

the outside of the door (Fig. 4A).

1. Drill (2) 1/8” x 1-1/4” deep holes

in the door if not already present.

Refer to template for fire-stop

prep locations.

2. Attach with flap up and

out using (2) #8 x 1/2”

self-tapping screws for

wood and metal doors.

B. Weather Conduit
(P/N 52-2847)

Install weather conduit on

NON FIRE-RATED exterior

doors only.

1. Carefully insert the weather

conduit into the ribbon cable

hole on the inside of the door

(Fig. 4B).

2. Place the O-ring around the

weather conduit on the out-

side and up against the door

(Fig. 4C).

of 1-1/2”
Diameter

(2) 1/8” Diameter
Holes Required

Fire Stop Plate

Slot

(2) Self Tapping

Screws #8 x 1/2”

for Wood and

Metal Doors

Fig. 4A

A. Fire Stop Plate (P/N 53-0033)

7/8”

1-1/2”

Outside of Door

Non-Cylinder Side

Fig.4B

Ribbon Cable Hole

Fig.4C

O-Ring

Outside of Door

Step #4 – Exterior Door Options

(2) #12-24 x 1/2”

Flat Head Screws

(Metal Doors)

(2) #12 x 1-1/4”

Flat Head Screws

(Metal Doors)

Fig. 3A

Harness exits

Non-Cylinder side