Profile series v.g1.5/lk mortise lock, Option #1 – forced / propped door (dm-), Installation – SARGENT Profile Series v.G1.5 Mortise Locks User Manual

Page 17

Advertising
background image

01/31/14

1-800-810-WIRE • www.sargentlock.com • A7855C 17

Copyright © 2014, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

Profile Series v.G1.5/LK Mortise Lock

321

4-pin

Connector

Installation

1. ElectroLynx® System Wiring Instructions (Fig. 1, 1A and Fig. 2):

a. Look for the mating part on ASSA ABLOY doors and frames.
b. Plug in all connectors during product installation (Fig. 2).
c. Hard wire door status switch as shown

2. Non-ElectroLynx® System Wiring Instructions (Fig. 1 and Fig. 2):

a. Cut the 4-pin connector off the Forced/Propped harness and hard wire to

non-ElectroLynx® two conductor door harness.

b. DM- requires two conductors.
c. Hard wire door harness to power transfer device.
d. Hard wire door status switch to power transfer device.

Fig. 2

Forced/Propped Door

Connector J4

Forced/Propped Door Option

ElectroLynx Wiring System

Door Status Switch

*Wire for switch contact closure

when door is opened - Typical

locations shown in Fig. 1

QC4A Electric Hinge

With 4-pin connectors and pigtail harness

ElectroLynx Door Harness

With 8 and 4-pin connectors

(Harness location dependent on door type)

DM- Prefix (52-3409)

Forced/Propped Door Harness

Ground

Tab E3

Option #1 – Forced / Propped Door (DM-)

D

C

B

A

Door

Inside

Escutcheon

Outside

Escutcheon

(TB2) Remote/Power

Unlock Connector

(TB1) Motor

Connector

1 - Red
2 - Black
3 - White (C)
4 - Green (*NC)

4 - Tan
3 - Pink

A

B

C

D

Fig. 1

1 - Red
2 - Black
3 - White
4 - Green

Advertising