SARGENT MPower 4000 User Manual

Page 14

Advertising
background image

80-9369-0901-021 (12-02 )

14

Operation:

Doors are normally closed and latched.

The doors will close after the hold open time delay has

elapsed.

Exit device allows egress at all times. Exit device allows

egress during power failure.

Activating the switch will retract the exit device then the

operator will open the door.

Notes:
1. Power input Door Operator Unit is at Power Input

Terminal Strip (not shown) 120VAC 60Hz.

2. Refer to Manufactures wiring instructions for Latch

Retraction Devices not shown.

3. Power Supply must be .900 Amps minimum per 56-

Latch Retraction Exit Device.

4. Set switch SW2 to position 3 for 1 second delay.

Electric Latch Retraction Exit Device Wiring (Pair)

JP4

GND +24V NO1 CO1 NC1 NO2 CO2 NC2

1 2 3 4 5 6 7 8

JP4

JP1

JP5

OFF

ON

SW1

P/A
A/D

RES1
RES2

0/0

RES1

A

UX2

GND

INV

OUTV

GND

R

F

T

GND

A

UX2

GND

PDET

GND

A

UX1

GND +24V NO1 CO1 NC1 NO2 CO2 NC2

NEU HOT GND

18VAC

1 2 3 4 5 6 7 8

14

13

12

11

10

9

8

7

6

5

4

3

2

1

JP1

0/0

RES1

A

UX2

GND

INV

OUTV

GND

RFT

GND

A

UX2

GND

PDET

GND

A

UX1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Lo
w
Ener

gy

P

o

wer Operator

#2

56-

Latch Retraction Exit Device

#1

56-

Latch Retraction Exit Device

#2

Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts

Door Operator 1

Door Operator 2

(+)

(-)

120 VAC

24VDC

Filtered and Regulated

Power Supply

*See Note 3

+24VDC

-24VDC

RED

BLACK

RED

BLACK

(+)

(-)