Vestibule function, Inside door outside door vestibule – SARGENT MPower 4000 User Manual

Page 7

Advertising
background image

80-9369-0901-021 (12-02 )

7

RELAY CONTACTS FOR

ELECTRIC STRIKE.

ELECTRIC LATCH RETRACT

EXIT DEVICE, MAGNETIC

LOCK, ETC.

See Note 3.

Notes:
1. Power input Door Operator Unit is at

Power Input Terminal Strip (not shown)
120VAC 60Hz.

2. Current draw must not exceed 0.500

amps at terminal Jp4 – 2.

Vestibule Function

Note 3:
If product being connected does
not have an integrated diode, one
must be installed across contracts
to protect relays . Suggested diode is
1N4001 or equivalent.
See pages 9 - 11 for illustration of use.

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1 2 3 4 5 6 7 8

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

NEU HOT GND

18VAC

GND +24V NO1 CO1 NC1 NO2 CO2 NC2

0/0

RES1

A

UX2

GND

INV

OUTV

GND

R

F

T

GND

A

UX2

GND

PDET

GND

A

UX1

6600/6700 SERIES DOOR OPERATOR
41-6700-0056 REV A MADE IN USA

OFF

ON

SW1

P/A
A/D

RES1
RES2

JP4

JP1

JP5

JP3

JP2

CL/AS DLY VEST DLY

EXSOL DLY

M. DLY

G

EM

G

H+

V
L

2
G

L1

MO

T

OR/SOLENOID

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1 2 3 4 5 6 7 8

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

NEU HOT GND

18VAC

GND +24V NO1 CO1 NC1 NO2 CO2 NC2

0/0

RES1

A

UX2

GND

INV

OUTV

GND

R

F

T

GND

A

UX2

GND

PDET

GND

A

UX1

DOOR OPERATOR

41-6700-0056 REV A MADE IN USA

OFF

ON

SW1

P/A
A/D

RES1
RES2

JP4

JP1

JP5

JP3

JP2

CL/AS DLY VEST DLY

EXSOL DLY

M. DLY

G

EM

G

H+

V
L

2
G

L1

MO

T

OR/SOLENOID

RELAY CONTACTS FOR

ELECTRIC STRIKE.

ELECTRIC LATCH RETRACT

EXIT DEVICE, MAGNETIC

LOCK, ETC.

See Note 3.

INSIDE DOOR

OUTSIDE DOOR

VESTIBULE

All Switches are either
Wall Switches, Card
Readers, Key Switches,
etc.
Normally Open Momentary
dry contacts

Inside Switch

Outside Switch

Inside

Corridor Switch

Outside

Corridor Switch

Operation:

Doors are normally closed.

Activating outside door switch will open the outside

door. After the vestibule time delay has elapsed, a
signal will be sent to the inside door which will open.

Activating the inside door switch will open the inside

door. After the vestibule time delay has elapsed, a
signal will be sent to the outside door which will
open.

Both doors will close when the hold open time delay

has elapsed.

Activating the inside Corridor door switch located

with-in the corridor will open the inside door only.
This door will re-close after the hold open delay has
elapsed.

Activating the outside Corridor door switch located

with-in the corridor will open the outside door only.
This door will re-close after the hold open delay has
elapsed.