Electronic control module (main pc board) – SARGENT MPower 4000 User Manual

Page 3

Advertising
background image

80-9369-0901-021 (12-02 )

3

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1 2 3 4 5 6 7 8

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

5

678

90

1

23

4

NEU HOT GND

18VAC

GND +24V NO1 CO1 NC1 NO2 CO2 NC2

0/0

RES1

A

UX2

GND

INV

OUTV

GND

R

F

T

GND

A

UX2

GND

PDET

GND

A

UX1

DOOR OPERATOR

41-6700-0056 REV A MADE IN USA

OFF

ON

SW1

P/A
A/D

RES1
RES2

JP4

JP1

JP5

JP3

JP2

CL/AS DLY VEST DLY

EXSOL DLY

M. DLY

G

EM

G

H+

V
L

2
G

L1

MO

T

O

R/SOLENOID

SW5 Rotary

Switch/Timer

Pot

SW4 Rotary

Switch/Timer

Pot

SW2 Rotary

Switch/Timer

Pot

SW3 Rotary

Switch/Timer

Pot

SW1 Dip
Switches

JP4 Terminal

Strip

JP1 Terminal

Strip

Fuse F1

1.5 amp,

2AG

Slo-Blo

Relay

K2

Relay

K1

Relay

K4

Relay

K3

JP2 Terminal

Strip

JP3 Terminal

Strip

Electronic Control Module (Main PC Board)

JP1 Terminal Strip – Maximum wire size 14AWG. For signaling only, do not make power input connections.

TERMINAL

D E S C R I P T I O N

1

0/0

– This terminal has two possible functions that can be used together or separately.

1.

– Upon initiation of a closed signal from a fire/ smoke alarm

panel, door will open and remain open until signal is terminated. Use with any JP1 ground.

2.

– Time is set with dip switch SW1 – 2 A/D. (OFF = 30

second delay, ON = 60 second delay) Use with any JP1 ground.

Override Open

Smoke Ventilation Door or Blow Open Door

Alarm Delay (30 second or 60 second time period)

2

RES1

This is not an active contact.

3

AUX2

– This is one of two secondary initiating switch contacts (JP1 – 10 is the other.)

For most applications it is equivalent to AUX1 JP1 – 14. For Vestibule Function use, it is the contact for a switch

located within the vestibule. Use with any JP1 ground.

Auxiliary 2

4

GND

Ground

5

INV

In Vestibule – Used for Vestibule Function. This contact must be connected to the JP1 – 6 terminal from another

unit to receive an initiating signal. The signal is then programed to initiate the unit by setting the VEST DLY rotary
switch/timer pot of the receiving unit. Use this contact with any JP1 ground.

6

OUTV

– Used for Vestibule Function. This contact must be connecter to terminal JP1 – 5 of another unit to

send an initiating signal. Use with any JP1 ground.

Out Vestibule

7

GND

Ground

8

RFT

– With the unit’s 3 Position Slide Switch in the “ON” position, a signal will open the door and

maintain an indefinite hold open until a second signal releases the door from hold open. Use with any JP1 ground.

Maintain Hold Open

This feature recommended for Power Operator Function. If using with the Power Assist Function, consult factory.

9

GND

Ground

10

AUX2

– Same as JP1 – 3 / AUX2 above.

Auxiliary 2

11

GND

Ground

12

PDET

– Permits wiring of a presence detector to prevent a closed door from opening or a door that is

fully open from closing. Use with any JP1 ground.

Presence Detector

13

GND

Ground

14

AUX1

Auxiliary 1 – Primary initiating switch contact. Initiates door power cycle. Must be Normally Open Momentary Dry

Contact. For Vestibule Function, the switch at outside of vestibule is connected to this terminal. (Outside switch to
outside unit’s JP1 – 14. Inside switch to inside unit’s JP1 – 14). Use with any JP1 ground.