Radio frequency function options, Option 1 option 2 – SARGENT MPower 4000 User Manual

Page 8

Advertising
background image

80-9369-0901-021 (12-02 )

8

Notes:
1. Power input Door Operator Unit is at

Power Input Terminal Strip (not shown)
120VAC 60Hz.

2. Current draw must not exceed 0.500

amps at terminal JP4 – 2.

JP4

JP1

JP5

OFF

ON

SW1

P/A

A/D

RES1

RES2

0/0 RES1 AUX2 GND INV OUTV GND RFT GND AUX2 GND PDET GND AUX1

GND

+24V

NO1

CO1

NC1

NO2

CO2

NC2

NEU

HO

T
GND

18V

A

C

1 2 3 4 5 6 7 8

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1 2 3 4 5 6 7 8 9 10 11 12 13 14

OPTIONAL SECOND

LOW ENERGY

POWER OPERATOR

RELAY CONTACTS FOR

ELECTRIC STRIKE.

ELECTRIC LATCH RETRACT

EXIT DEVICE, MAGNETIC

LOCK, ETC.

See Note 3.

GREEN (NO)

BLACK

WHITE (C)

RED

RF

RECEIVER

WIRING FOR

STANDARD

MOMENTARY

HOLD OPEN

FUNCTION

GREEN (NO)

BLACK

WHITE (C)

RED

RF

RECEIVER

WIRING FOR

TOGGLE / MAIN-

TAINED

HOLD OPEN

FUNCTION

OPTION 1

OPTION 2

Radio Frequency Function Options

Note 3:
If product being connected does
not have an integrated diode, one
must be installed across contracts
to protect relays . Suggested diode is
1N4001 or equivalent.
See pages 9 - 11 for illustration of use.

Operation:
Option1.

Option 2.

Door is normally closed.
Activating wireless switch or hand held

wireless transmitter will open the door.

Door will close after hold open delay

elapses.

Door is normally closed.
Activating a wireless switch or hand held

wireless transmitter will open the door.

Door will remain in indefinite hold open

until wireless switch or hand held
transmitter is activated a second time
causing the door to close.