Installation instructions, Jp10 / jph10 jps / jpsh jcp / jcpsh – SARGENT 1331 Series Aluminum Closer User Manual
Page 4

·
Select angle of opening and use dimensions shown on
Page 4 and Dimension Chart below to locate 4 holes on
stop side of door for closer body (or 1331-D drop plate,
only if required, see page 5) and 5 holes on stop and/or
rabbet for Soffit Plate. For applications not covered in
these instructions, a separate template will be required.
·
Prepare door and frame for fasteners. See “Preparation
for Fasteners”, Page 2.
·
Set approximate closer power for door size using Power
Adjustment Chart below. Use 5/16" wrench to adjust
Power Adjustment Shaft (set at 8 turns from factory) 20
turns maximum. Turn nut CLOCKWISE to Increase,
COUNTER-CLOCKWISE to Decrease power. See Page
6 for the illustration of this step.
·
Mount 1331-D Drop plate ... only if required (see Page 5).
·
Install closer with power adjustment shaft toward hinge
edge of door.
·
For JP10H arm only, check that hand of arm matches
hand of door. See arm illustration on page 2 for location
of arm handing mark.
·
wrench, turn pinion shaft 50° or more to permit proper
alignment of arm mark with pinion flat -
‘L’ for Left hand door.
‘R’ for Right hand door.
See Arm Mounting Detail and Main Arm Installation at
right below. (Caution: Closer arm is under spring
tension and may be difficult to rotate.)
·
·
... use spacer blocks 582-1 or 581-1, if required.
(Caution: Closer arm is under spring tension and may
be difficult to rotate.)
·
Make closer adjustments (see page 6) before installing
cover
NOTE: DO NOT back valves out of closer or a leak will
result.
·
With door closed, closer valves ‘S’ and ‘L’. Then with a
Reopen valves ‘S’ and ‘L’ by turning counter clockwise.
With door closed, align soffit plate with mounting holes in
frame. Fasten soffit plate to frame with flat head screws
provided.
Install cover (see page 6).
Installation Instructions
JP10 / JPH10
JPS / JPSH
JCP / JCPSH
Interior
Exterior
Interior
Exterior
28-32 in
0.7-0.8 m
33-36 in
0.85-0.9 m
37-42 in
0.95-1.05 m
43-48 in
1.1-1.2 m
Door
Size
Full Clockwise Turns of Closer Power Adjustment Shaft
Power Adjustment Chart
NOTE: Maximum of 20 turns (360°) of Power Adjustment Shaft.
Closer is shipped set at mid power setting.
7
9
9
10
10
12
11
12
13
15
13
14
16
18
15
16
JP10
JPH10
JPS
JPSH
JCPS
JCPSH
Butt
Hinges
or
Offset
Pivots
Center
Pivots
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
85°-
90°
90°-
95°
95°-
100°
100°-
105°
105°-
110°
110°-
115°
115°-
120°
120°-
180°
1-1/4
(32)
7
(178)
3-3/4
(95)
9-1/2
(241)
3-3/8
(86)
8-7/8
(225)
3-1/4
(83)
8-3/4
(222)
5-1/2
(140)
11
(279)
5-3/8
(137)
10-7/8
(276)
4-3/4
(121)
10-1/4
(260)
4-5/8
(117)
10-1/8
(257)
4
(102)
9-1/2
(241)
3-7/8
(98)
9-3/8
(238)
2-3/4
(70)
8-1/4
(210)
2-5/8
(67)
8-1/8
(206)
2-1/8
(54)
7-5/8
(194)
2
(51)
7-1/2
(191)
Dim
A
B
A
B
A
B
Installation Dimensions Chart
1) Start (wrench)
here (bottom
shaft)
2) Rotate 50°
to here
3) Install arm
here (see below
for details)
Arm Mounting Detail
L
R
Y
S
Z
L
R
Y
S
Z
Power Adjustment Shaft
Pinion Flat
Arm Mark
Left Hand Door
Door Swing
Main Arm Installation Instructions
Power Adjustment Shaft
Pinion Flat
Arm Mark
Right Hand Door
Page 4
A8160A
Copyright © 2013 Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing is prohibited.
63-8160-6000-999