Prefix 80 series exit device, System wiring examples (continued) 9 – SARGENT 57 - Delayed Egress User Manual

Page 17

Advertising
background image

Return

Return

Red (+)

Black (-)

Electromagnetic

Lock

7, Brown (Mag

-

)

8, Yellow (Mag +)

3520 24VDC 1.0AMP Regulated and Filtered Power Supply

110-120 VAC

Connector

to power on LED

HOT

NEUT

GND

1 2 3

AC

F

Low voltage AC

From transformer

AC

DC DC

Output

NOTE: This drawing shows the

BPS Series. The PM Series has no

line voltage input, fuse or connector

to power on LED.

2.5 AMP polyswitch breaker

Red
Black

Unconnected

terminal for switch

hookup

Battery Pack

Wiring Notes:
1. Rail, raceway, electric hinge and

pigtail 8-pin connector terminations

and wire colors all match.

2. A fire alarm tie-in is required on fire

rated openings.

3. The fire alarm contact (when

required) must be wired to drop
24VDC power to rail.

In this case, terminate fire alarm

contact between the red (+24VDC)
wire and supply +24VDC output.

Sample Wiring #3 – 57- Exit Device with Fire Alarm, Keypads and Fail Safe ET

During a fire alarm condition, the contact opens which de-energizes the rail electromagnet and allows immediate
egress. A valid code entry at the 4291 (Inside) keypad shunts the 57- exit device and allows egress for a time period
programmable at this keypad. A valid code entry at the 4292 (Outside) keypad unlocks the 773 or 775 Fail Safe ET and
shunts the 57- exit device and allows ingress for a time period programmable at this keypad.

Line voltage

fuse (1 AMP)

System Wiring Examples (Continued)

9

Voltage adjust for

battery backup

17 1-800-810-WIRE • www.sargentlock.com • A7743C

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

04/15/13

57- Prefix 80 Series Exit Device

Advertising