Prefix 80 series exit device, Troubleshooting (continued) 11, Default factory setting for 57- shown – SARGENT 57 - Delayed Egress User Manual

Page 22

Advertising
background image

FUNCTION

JUMPER

57-

J5-

1 & J5-2

59-STD

J5-2 & J5-3

J5

1 2 3

1. When the rail is armed (in Delayed Egress Mode) and the door is closed and latched, the Green (default) or

Red LED and the Green Diagnostic LED should be ON only. All other diagnostic LEDs should be OFF.

2. With the rail armed, depressing the rail push bar slightly will turn the Red Diagnostic LED ON. The rail

should go into alarm immediately (no nuisance delay) or after being pressed in for 1 second (1-second

nuisance delay). The rail will be in the irreversible alarm mode – Insert Green and Red LED flash and the rail

horn sounds. After a standard delay of 15 seconds (or 30-second optional delay), the external magnet de-

energizes and passage is allowed. The rail horn will continue to sound until the rail is reset either with a key

or remotely.

3. When a Door Status switch is used and the door is opened the Orange Diagnostic LED will turn ON, which

indicates that the door is not secure. When NOT using a Door Status switch, the Blue wire should be con-

nected to Black (-Return). In this case, the LED will always be OFF.

**

Black ( - )

57-80 Series

Blue

DSS *

MINIMUM REQUIREMENTS FOR ARMING RAIL (DELAYED EGRESS MODE)

* To Arm 57- Rail– The

Blue Door Status Switch (DSS) wire must be connected

directly to the Black wire (-Return) or the contacts must be closed as shown.

The White wire (formerly Green) must be connected to the Black wire (-Return)

as shown.

-Return

+24VDC

* Only these (3) wires are needed to arm rail along with the correct

LBM switch and Push Rail Switch position as shown before

**

Fire Alarm Contact (if required)

Red ( + )

Default factory setting
for 57- shown

NOTES

With Rim, Mortise and Vertical Rod exit devices:
When jumper is missing or in wrong position, the Yellow Diagnostic LED turns ON. To locate (J5) jumper,

remove Insert Assembly amd Insert Assembly Plate:

Troubleshooting (Continued)

11

22 1-800-810-WIRE • www.sargentlock.com • A7743C

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

04/15/13

57- Prefix 80 Series Exit Device

Advertising