Prefix 80 series exit device, Troubleshooting, Visible insert leds function – SARGENT 57 - Delayed Egress User Manual

Page 21: Diagnostic leds function, Diagnostic leds, Insert leds

Advertising
background image

Visible Insert LEDs

Function

Green (Default) or Red ON only

Rail is Armed - Delayed Egress Mode

Red(Default) or Green ON only

Rail is Disarmed – Maintained (Free) Egress Mode

Red (Default) or Green “Flashing”

Rail is in Momentary Egress Mode

Green and Red “Alternate”, Rail Horn is ON

Rail is in violation

Diagnostic LEDs

Function

Yellow

ON –

*

Jumper is missing or in wrong position

OFF – should always be OFF

Green (Magnet)

ON – External Magnet is energized (+24VDC from main board)

OFF – External Magnet is de-energized

Red (Push Rail Switch)

ON – Rail Push Bar is depressed
OFF – Rail Push Bar is released

Orange (Door Status Switch)

ON – Door Status Switch is open. Door is open/violated.
OFF – Door Status Switch is closed. Door is closed and secure.

*See Jumper position and function table on following page

Troubleshooting

The tables below are provided to assist in the installation and troubleshooting of the 57- exit device.

11

IMPORTANT: Always remove power to the rail before disconnecting or reconnecting connectors at the

57- PCB module assembly. Disconnect the 24VDC Power Supply or remove the Red (+24VDC)

power wire at the rail.

The diagnostic LEDs are visible after install with end cap removed.

The following table lists the status and function of the (2) Green/Red LEDs located on the rail insert.

Diagnostic

LEDs

Refer to the following table and notes for an explanation of each LED’s function.

Insert LEDs

21 1-800-810-WIRE • www.sargentlock.com • A7743C

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

04/15/13

57- Prefix 80 Series Exit Device

Advertising