Electroguard, Prefix 80 series exit device, 4installation instructions (continued) – SARGENT FM8700 Surface Vertical Rod Exit Device User Manual

Page 19

Advertising
background image

Chassis

mounting
holes

Inside of door

Opening in
chassis for

wire

Chassis

arm

MOUNT CHASSIS
1. Feed wire and connector through chassis as shown;

mount chassis
2. Snap the ElectroLynx connectors together and

gather excess wire in the top section of the chassis.
Wire tie in place.

3. Finish installation per instruction sheet A6705

and Section 10 within this manual

Rail assembly

Truss head

screws

Rail wire &

connector

Push rail

Latchbolt

Lever

Lever arm

H. Installing 59-8900/12-59-8900 Series Mortise Lock Exit Device (continued)

IMPORTANT: Surface of door where exit

device is to be applied must be flush.

Clear away any raised projections to

allow exit device to rest on flat surface

of door.

4

Installation Instructions (Continued)

19 1-800-810-WIRE • www.sargentlock.com • A7690E

Copyright © 2013, Sargen

t Manufacturing Company