background image

Pigtail harness assemblies with 8

& 4-pin connectors (shown). Pigtail

harness with 8-pin connectors

only may be supplied depending

on application.

Electric hinge with 8 & 4-pin connectors (shown).

Electric hinge with 8-pin connectors only may be

supplied depending on application

Rail-to-Hinge Raceway

harness with 8 & 4-pin

connectors

4

3

2

1

59- 80 Series Rail with

8 & 4-pin connector

and 3 flying leads

Note: Typical raceway location is

shown. Other locations may exist

depending on door type

Exit Device Plug-in Connector Installation

Insert bracket mounting screw through *ground ring terminal. Fasten mounting bracket with mounting bracket

screws (ring terminal).

Finish mounting exit device per instruction sheet provided.

Plug rail connectors into raceway connectors. Then feed through 1” hole

in door. Install rail mounting bracket with two screws supplied. Install rail
insert and end cap.

To insure trouble-free operation, check that the push rail can be fully depressed.

On vertical rod exit devices, adjust rods and check that the latch bolts do not go into hold- back position
until the push rail is fully depressed.

Go to (A) if wiring now. Go to (B) if wiring is to be done later .

A. Refer to Input/Output Terminations - Section 11 through Wiring Examples - Section 14

Wire to flying leads on pigtail harness(es) as required using connectors allowed by local code. Plug pigtail harness
connector(s) into electric hinge connector(s)

Feed harnesses through frame prep and mount electric hinge.

Ensure wiring is correct; apply power and test exit.
Refer to operating instructions in section 9.

B. Plug pigtail harness connector(s) into electric hinge connector(s).

Feed harness(es) through frame prep and mount electric hinge.

*Ring terminal must be grounded as indicated.

8

!

Plug raceway connector(s) into electric hinge connector(s) then feed through door prep.
Note: Electric hinge will have two 8-pin connectors or two 8-pin and two 4-pin connectors. Mount electric
hinge to door side only.

1

2

3

4

Mounting

bracket

1” dia. hole

in door

Screw

locations

Ring terminal

(from harness)

25 1-800-810-WIRE • www.sargentlock.com • A7690E

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

04/15/13

Electroguard

®

59- Prefix 80 Series Exit Device

Advertising