5

Factory Default Settings

Default factory presets for the Electroguard

®

are as follows:

Status

LEDs/Time

Horn

Armed (Delayed Egress)

Solid GREEN

Off

Momentary Egress (Passage Delay) Flashing RED for (5) seconds

Off

Disarmed

Solid RED

Off

Alarm

Flashing RED & GREEN (15)
seconds for egress

On

Nuisance Delay

(1) second

On

Nuisance Audible

On

Momentary Egress Time

(5) seconds

Reverse LED

RED (Armed)

Handing

”Top” LED (Armed) for
LHRB or RHRB

If default feature settings need to be changed, carefully slide the insert assembly
from the rail assembly to make the proper DIP switch adjustments (see Section 5 -
Electroguard DIP Switch Settings).

OFF

ON

For example, solid RED can be set to indicate that the rail is ”Armed” with solid
GREEN indicating that rail is ”Disarmed”.

NOTE: Use caution when
removing insert assembly
to avoid damaging the rail
harness connected to the
PCB module assembly.