Power mode wiring – SARGENT 56 - Latch Retraction User Manual

Page 5

Advertising
background image

A7925D 5

06/09/11

Copyright © 2009 Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

56- Electric Latch Retraction Exit Devices

Installation and Wiring Instructions

With Optional 53- Latchbolt; 55- Request to Exit;

and TL- (SARGuide) Connection Instructions

FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com

Non-ElectroLynx Opening Installation

Standard door with standard electric hinge: Molex connectors with flying leads can be purchased separately (Fig. 9).

2. POWER MODE Wiring

ElectroLynx Opening Installation

This is the simplest installation method, requiring the installer to plug the ElectroLynx connectors from the exit device to the
harness to the hinge and then to the pigtail, which is connected to the access control system.

Requirements

56- Exit device

3” ElectroLynx connector harness (not supplied with 56- device)

McKinney QC ElectroLynx hinge (type of hinge depends on the application)

ElectroLynx door

Fig. 8 ElectroLynx

POWER MODE

Wiring

3” ElectroLynx Harness

With 8-pin Connector

(purchased separately)

8-pin F

8-pin M

8-pin M

MoLEX boTh ENDS

MoLEX To PINS

3 INCH

QC-C003

QC-C003P

6 INCH

QC-C006

QC-C006P

12 INCH

QC-C012

QC-C012P

Fig. 10 Non-ElectroLynx

POWER MODE

Wiring

56- Wires with ElectroLynx Connector Removed

Loose wires with no termination

connected with wire nuts

Non-ElectroLynx

Electric Hinge

To identify part numbers and order harness(es), visit the McKinney
website,

www.mckinneyhinge.com, and search the catalog for ElectroLynx.

If Molex pinned connectors are not available, remove the ElectroLynx connector from the 56- Exit Device and wire nut the
56- wires to the wires from the electric hinge (color coordinating wire colors is recommended).

Fig. 9 Molex with 12-pin Connector Pinned

1 - Black (56- 0VDC)
2 - Red (56- +24VDC)
3 - White (53- C)
4 - Green (EG)
5 - Orange (53- NC/NO)*
6 - Blue (55- C)
7 - Brown (55- NO)
8 - Yellow (55- NC)

1 - Black (56- 0VDC)
2 - Red (56- +24VDC)
3 - White (53- C)
4 - Green (EG)
5 - Orange (53- NC/NO)*
6 - Blue (55- C)
7 - Brown (55- NO)
8 - Yellow (55- NC)

*NO/NC (Normally Open/Normally Closed)
is selectable on controller (refer to 53-
DIP Switch Instructions in Section III).

Factory preset is NO.

4-pin F

Not Used

4-pin F

Not Used

Advertising