56- Electric Latch Retraction Exit Devices

Installation and Wiring Instructions

With Optional 53- Latchbolt; 55- Request to Exit;

and TL- (SARGuide) Connection Instructions

FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com

3. POWER MODE Typical Wiring

For use when wiring in

POWER MODE.

Notes:

Onboard timer will not function in

POWER MODE.

Add external time delay if necessary.

The switch is wired between the power supply
and the load. Do not cycle the power supply.

24VDC

Power Supply

QC8 Electric Hinge

0V (Black)
+24V (Red)
EGND

Green (EGND)

Red (+24V)

Black (0V)

Maintain

or Relay Switch, i.e.,

Card Reader, Access

Control, etc.

( + )

( - )

( NO )

( NC )

Fig. 11 56- 80 Series Exit Device Typical POWER MODE Wiring

For 56- applications using the optional 53- latchbolt monitor switch (53-56-), pin 5 of the 8-pin ElectroLynx connector will be
either a NO contact or NC contact depending on the position of the DIP switches on the motor controller faceplate.

4. Configuration Instructions DIP Switch Settings (53-)

Fig. 12 DIP Switch Setting

for 53- Latch bolt Monitoring

No (Default) Shown

Fig. 13 NC alternative

DIP Switch Setting