Cleaning Out Meters
NOTE: Shut off sliding seed tubes before at-
tempting to clean out seed meters.

For seed meter clean out:

1.

Position tarp or buckets under the opener(s)
whose meter(s) you will be cleaning out.

Refer to Figure 37

2.

Remove retaining clip and pull pin.

Refer to Figure 38

3.

Pull up on meter clean out door to open.

4.

When meter is empty, push meter clean out
door back to its original position to close.

NOTE: You may need to shake the clean out
door a little before closing to make sure all
seeds fall out.

Refer to Figure 39

5.

Replace pin and retaining clip.

Figure 37

Meter Clean Out

22856

Retaining clip

Clean out door

Figure 38

Meter Clean Out Door

22857

Clean out door

Figure 39

Meter Clean Out Pin