Great Plains 1525P Operator Manual User Manual

Page 60

Advertising
background image

1525P, 1510HDP

118-949M

8/14/2006

58

Refer to Figure 65

6.

Check for excess wear on meter slide (1).
Slight wear at the top corner is normal.

7.

If slide is not excessively worn, stop here.
If it is, continue with the following steps to
replace.

Refer to Figure 66

8.

Remove retaining clip and pin from meter.

NOTE: Meter slide is spring loaded and the
two meter slide springs will be released
when you pull the pin. Use care not to lose
pins and springs.

9.

Check removed pin for wear and replace if
worn.

Refer to Figure 67

10. Remove meter slide (1) with springs (2).

11. Place springs in new meter slide and in-

stall in meter.

12. Reinstall seed meter wheel. Refer to page

38.

Figure 65

Meter slide location

18269

Retaining
clip

Figure 66

Meter slide retaining clip

19190

Figure 67

Meter slide

18269

Advertising
This manual is related to the following products: