Grommet maintenance – Great Plains 1525P Operator Manual User Manual

Page 63

Advertising
background image

8/14/2006

118-949M

61

Maintenance and Lubrication

Seed Tube Maintenance

Inner Sliding Seed Tube Replacement
Clean inner sliding seed tube if it will not slide. Re-
place inner sliding seed tube if you see any visible
cracks.

Refer to Figure 73

To replace inner sliding seed tube follow these
steps:

1.

Make sure seed box is empty.

2.

Loosen bottom clamp (1).

3.

Pull inner sliding seed tube (2) out of seed
meter grommet and pull down out of outer slid-
ing seed tube (3).

4.

Inspect outer sliding seed tube for wear and re-
place if necessary.

5.

Place new inner sliding seed tube inside outer
sliding seed tube. Make sure the chamfer on the
inside of the tube is up as shown.

6.

Fit inner sliding seed tube into seed meter
grommet and tighten clamp.

Outer Sliding Seed Tube Replacement
Replace outer sliding seed tube if you see exces-
sive wear on the inside of the tube.

Refer to Figure 74

To replace outer sliding seed tube follow these
steps:

1.

Make sure seed box is empty.

2.

Loosen bottom clamp (1).

3.

Pull inner sliding seed tube (2) out of seed
meter grommet and pull down out of outer slid-
ing seed tube (3).

4.

Inspect outer sliding seed tube for wear and re-
place if necessary. Loosen top clamp (4) and
pull outer sliding seed tube from seed box
grommet.

5.

Fit new outer sliding seed tube into seed box
grommet. The distance from seed box grommet
lip to the top of the clamp should be no more
than 3/16 inch, see insert. The outer sliding
seed tube must extend above the rubber grom-
met by 1/2” to 5/8” for 25 series openers, see in-
sert. Tighten clamp (4).

6.

Place new inner sliding seed tube inside outer
sliding seed tube. Make sure the chamfer on the
inside of the tube is up as shown.

Figure 73

Sliding seed tubes

18298

Outer sliding
seed tube

Inner sliding
seed tube

7.

Fit inner sliding seed tube into seed meter grom-
met and tighten clamp.

8.

Replace inner sliding seed tube inside outer
sliding seed tube as shown, fit into seed meter
grommet and tighten clamp (1).

Grommet Maintenance
Periodically check seed meter and seed box grom-
mets for weathering or cracking and replace as
necessary. Check sliding seed tubes at this time to
make sure they slide freely.

Figure 74

Sliding Seed Tube Replacement

23101

Advertising
This manual is related to the following products: