Console functions, Calibration – Great Plains 1525P Operator Manual User Manual

Page 75

Advertising
background image

8/14/2006

118-949M

73

Veris Drive Operating Instructions

Console Functions

Refer to Figure 82

The use of each key is as follows:

On/VR key—turns drive system on.

Press twice for VR mode. Note: Engage
key must also be pressed to start drive
operation.

Off key: used to shut off Console.

Function key: used in calibration mode

and to program Console for VR recipes.

Up/down arrow keys: used to change

rates manually, to set calibration num-
bers, and VR controller options.

Engage key: press to start drive.

NOTE: Drive will not run unless light above
key is illuminated.

NOTE: Figure 82 shows Main Operating
Screen in manual mode.

Calibration

Refer to Figure 83

1.

Turn on Controller Console by pressing
On/VR key. Green light above On/VR key
will illuminate when power is on. Adjust
desired planting rate by using the Up/
Down arrow keys to change the Set rate.

2.

Set the desired Rate by using the Up/
Down arrow keys.

Refer to Figure 84

3.

Press Function key until Calibration
Number window appears. Select drive
calibration number based on row spacing
and metering wheel, from chart on page
78. Use Up/Down arrow keys to set Cali-
bration number.

Figure 82

Figure 83

Figure 84

22710

22715

22716