Operator’s manual – Great Plains DICKEY-john Auto Section Control User Manual

Page 12

Advertising
background image

OPERATOR’S MANUAL

Auto Section Control System

11001-1561B-201207

10 / AUTO SECTION TERMINAL

Field Map Descriptions:

(1) Path-driven field outline - Driving an external field path provides a visual

outline of the field. Automatic row shutoff does NOT occur when a section

extends past the outline.
(2) Seeded area - Areas planted with seed is defined in green.
(3) Nonseeded area - Any areas not seeded remain in yellow or brown
(4) Over applied area - Areas with twice applied seed appears in blue

IMPORTED EXTERNAL BOUNDARY

Field maps created in a PC farm software that is compatible with the

IntelliAg Task Control application can be imported to the Auto Section

Control terminal. Automatic row shutoff occurs when any defined external

and internal boundaries are entered.
(1) External boundary - Any defined boundary outside of the field appears in

gray (day mode) or black (night mode). Rows automatically shut off if a

section extends past the external boundary.
(2) Internal boundary - Any defined boundary within the field appears in

gray (day mode) or black (night mode). Rows automatically shut off if a

section extends into the internal field boundary.
(2) Seeded area - Areas planted with seed are defined in green.
(3) Nonseeded area - Any areas not seeded remain in yellow (day mode) or

brown (night mode).
(4) Over applied area - Areas with multiple applications appears in blue.
Figure 9
External / Internal Boundary

Internal
Boundary

Field
(yellow)

Seeded
Area
(green)

External
boundary
(gray)

Advertising