Operator’s manual – Great Plains DICKEY-john Auto Section Control User Manual
Page 51

OPERATOR’S MANUAL
Auto Section Control System
11001-1561B-201207
DIAGNOSTICS / 49
CLUTCH SECTION CHECK
A recommended pre-test to verify correct module and clutch assignment
ensures that clutches turn on and off appropriately.
To perform test:
1. At the Diagnostics screen, press the Section Check button.
1. Enter the cycle time duration of turning clutches on and off.
2. Select the type of test to perform
– All output test
– Single output test
3. Press the Start Test button to begin test.
4. Press the Stop Test button to end test.
IMPORTANT: Master switch and all clutch switches must be ON, if
equipped.
Figure 49
Clutch Section Check
Cycle Time
Desired cycle time duration of turning clutches on and off during test.
All Output Test
Turns all clutches on and off at the same time.
Single Output Test
Selects which section to perform an individual section test. Plus button
goes to next higher section. Minus button goes to next lower section.
Start
Test