OPERATOR’S MANUAL

Auto Section Control System

11001-1561B-201207

DIAGNOSTICS / 49

CLUTCH SECTION CHECK

A recommended pre-test to verify correct module and clutch assignment

ensures that clutches turn on and off appropriately.
To perform test:

1. At the Diagnostics screen, press the Section Check button.

1. Enter the cycle time duration of turning clutches on and off.

2. Select the type of test to perform

– All output test

– Single output test

3. Press the Start Test button to begin test.

4. Press the Stop Test button to end test.

IMPORTANT: Master switch and all clutch switches must be ON, if

equipped.

Figure 49
Clutch Section Check

Cycle Time

Desired cycle time duration of turning clutches on and off during test.
All Output Test

Turns all clutches on and off at the same time.
Single Output Test

Selects which section to perform an individual section test. Plus button

goes to next higher section. Minus button goes to next lower section.

Start

Test

Advertising