OPERATOR’S MANUAL

Auto Section Control System

11001-1561B-201207

52 / TROUBLESHOOTING

• Clutch assignment may be incorrect.

– Verify that output modules have been correctly assigned to rows at

the Module Configuration screen.

– Verify that row shutoff switches are correctly assigned to

corresponding outputs.

– Run a Clutch Section check to verify the order of clutch sections

shut on and off correctly (refer to Diagnostics screen).

auto section control screen shows gaps in swath pattern (start/stop)

– Driving to wide.

– GPS accuracy issue.

– Verify Physical Layout screen to verify layout is correct.

AUTO SECTION CONTROL SCREEN SHOWS GAPS IN
SWATH PATTERN (START/STOP)

– Swath coverage map is drawn based on seed flow. If stopped in the

field, there will be a slight delay in seed flow when starting up

causing a slight skip in the coverage map, i.e., seeding rate must

exceed row fail rate before coverage can be painted.

AUTO SECTION CONTROL SCREEN SHOWS OUT OF
FIELD

• Wrong field loaded.

• The field is too far out of range to display on the screen.

ROWS ARE NOT SHUTTING OFF AND TURNING ON AS
EXPECTED

• Implement measurements could be incorrect.

– Verify that measurements were entered as described at Physical

Layout screen.

– X measurements should be taken from the hitch pivot point to

where the seed is placed in the ground.

– Y coordinates are measured from implement center to the center of

each channel.

– Verify implement/channel assignment are correct at the Physical

Layout screen.

• Verify that the correct Implement Layout type was selected (3 point

hitch, towed hitch, rigid cart mount, or tow-behind cart).

• When operating in Monitor only mode there are no rows assigned to a

channel on the IntelliAg. However, row assignment must be entered at

the Physical Layout screen for Auto Section to perform correctly.

• If operating with only one control channel, the Y coordinate on the

Physical Layout screen should remain at “0”.

• Clutch assignment may be incorrect.

– Verify that output modules have been correctly assigned to rows at

the Module Configuration screen.

– Verify that row shutoff switches are correctly assigned to

corresponding outputs.

– Run a Clutch Section check to verify the order of clutch sections

shut on and off correctly (refer to Diagnostics screen).

• Swath control is not in Auto mode.