‘Magic Eye’ GREEN
Whenever the Bluetooth

®

sensor dome is ready to start a test, the ‘magic

eye’ will show green. After every drop the test data will be transferred to
the testing computer. During data transfer the ‘magic eye’ will switch to
blue. As soon as the data transfer is finished the ‘magic eye’ will switch
back to green, indicating that the device is ready for the next drop.

6.5 Continuous Measuring Mode

If the test shall be performed on several testing points close to each other,
the testing computer can be operated in ‘CONTINUOUS MEASURING
MODE’. In this mode tests can be performed in quick succession,
without the need to operate the testing computer between each
individual test.

To turn on the ‘CONTINUOUS MEASURING MODE’, press the ‘SELECT’
button during ‘STATUS REQUEST’. In the ‘MAIN MENU’ press the
‘SELECT’ button, until the arrow is positioned on the menu entry
‘CONNECTION’. Then press the ‘START’ button to select the menu
‘CONNECTION’. Finally, press the ‘START’ button again to select the
menu ‘STAND-BY TIME’.

The stand-by time is the time that the testing computer will wait for the
next test to start before switching itself off due to timeout. Use the
‘SELECT’ button to increase the wait time by increments of five minutes,
up to a maximum wait of 30 minutes. Confirm the set time with the
‘EXIT’ button. Continue pressing the ‘EXIT’ button, until the screen shows
‘STATUS REQUEST’ again. Then start the first test, as described above.
The voice output will confirm if the ‘CONTINUOUS MEASURING
MODE’ is turned on successfully by announcing ‘CONTINUOUS
MEASURING MODE ON’. It will then direct you through the test, as
described above. At the end of the test, move to the next testing point.
Firmly latch the drop weight back into the release mechanism. This will
start the next test without needing to operate the testing computer.

If no new test is started within the set wait time, the testing computer will
switch off automatically.

The ‘STAND-BY TIME’ can be set back to ‘00 MIN’ by using the ‘PRINT’
button. The testing computer will then go back to single measuring mode
and will operate with the default switch-off after three minutes of inactivity.

MAIN MENU

PRINT FROM SD-CARD

LANGUAGE

GPS / TIME

INTERNAL MEMORY

SERVICE

CONNECTION

EXIT

SET

MENU CONNECTION

STAND-BY TIME

BLUETOOTH PAIRING

EXIT

SET

STAND-BY TIME 00 MIN

EXIT

-

+

STAND-BY TIME 10 MIN

EXIT

-

+

STATUS DISPLAY

D I

3 0 / 0 6 / 1 3 1 5 : 5 0 : 2 2

OK

OK

OK

GPS

6 , 3 V

1 0 0