7.7.3 Device Type 10 / 15 Kg

Turn on the device by pressing the ‘START’ button. Enter the ‘MAIN
MENU’ by pressing the ‘SELECT’ button. Use the ‘SELECT’ button to
move the arrow and select ‘SERVICE’ from the menu. Press the ‘START’
button (SET) to enter the ‘SERVICE’ menu.

Use the ‘SELECT’ button to move the arrow and select ‘10 / 15 KG
MODE’ from the menu.

Press the ‘START’ button (SET) to enter the ‘10 / 15 KG MODE’ menu.

The display will show plate diameter and the currently selected device
version with 10 or 15 kg loading device. You can change the device
version by pressing the ‘START’ button (SET). The 20 kg loading device
cannot be selected; this is reserved for planned future changes.

Press the ‘RESET/OFF’ button (EXIT) to return to the ‘SERVICE’ menu.
Press the ‘RESET/OFF’ button (EXIT) again to return to the ‘MAIN
MENU’. Press the ‘RESET/OFF’ button (EXIT) again to return to the
‘STATUS REQUEST’. Pressing the ‘START’ button will start the test
procedure.

7.7.4 Display Contrast

Turn on the device by pressing the ‘START’ button. Enter the ‘MAIN
MENU’ by pressing the ‘SELECT’ button. Use the ‘SELECT’ button to
move the arrow and select ‘SERVICE’ from the menu. Press the ‘START’
button (SET) to enter the ‘SERVICE’ menu.

Use the ‘SELECT’ button to move the arrow and select ‘DISPLAY
CONTRAST’ from the menu.

Press the ‘START’ button (SET) to enter the ‘CONTRAST’ menu.

The display contrast may be adapted by using the ‘PRINT’ (-) and ‘SELECT’
(+) buttons.

Press the ‘RESET/OFF’ button (EXIT) to return to the ‘SERVICE’ menu.
Press the ‘RESET/OFF’ button (EXIT) again to return to the ‘MAIN
MENU’. Press the ‘RESET/OFF’ button (EXIT) again to return to the
‘STATUS REQUEST’. Pressing the ‘START’ button will start the test
procedure.

SERVICE MENU

INPUT TEST

VERSION

10/15/20 Kg MODE

DISPLAY CONTRAST

PC SERVICE

CALIBRATION MODE

EXIT

SET

10 / 15 KG MODE MENU

MODE = 300mm / 10 Kg

EXIT

SET

10 / 15 KG MODE MENU

MODE = 300mm / 15 Kg

EXIT

SET

CONTRAST MENU

CONTRAST = 190

EXIT

+

SERVICE MENU

INPUT TEST

VERSION

10/15/20 Kg MODE

DISPLAY CONTRAST

PC SERVICE

CALIBRATION MODE

EXIT

SET

Advertising