Ne215 counter connecting and operating – Baumer NE215 User Manual

Page 10

Advertising
background image

10

NE215

Counter connecting and operating

3.6 Executing the test routine

The test routine is described below.

To start test

Press the

2

and

Druck

key simultaneously.

Switch the counter on.

All the display segments will be displayes automatically in
sequence and are therby tested for functional capability.

Test extension

Using the

key, test the keyboard, the inputs, outputs and

interface in sequence.

No machine fuctions may connected when the outputs are tested.

Keyboard test

Input test

Inputs can be triggered simultaneously or individually. A display
is only provided when a signal is applied.

Output test

Press keys

1

,

2

and

3

.

The outputs are now activated.

Reset the outputs with the

key.

Interface test

Display: Model and program number

Display: Program date and version

End of test

The test routine is terminated, the counter is now in the operating
mode.

Advertising