Ne215, Programming mode – Baumer NE215 User Manual

Page 20

Advertising
background image

20

NE215

Programming field 4

Line 43

Baud rate

0 * 4800 baud
1

2400 baud

2

1200 baud

3

600 baud

Line 44

Parity

0 * Even parity
1

Odd parity

2

No parity

Line 45

Address

* 0

1-99

Line 46

Stop bits

0 * 1 Stop bit
1

2 Stop bits

●

At the conclusion of these programming lines, a broken line will
appear in the display, signifying the competion of the fourth
programming segment.

To leave programming mode

Press the

key.

●

Counter now reverts to the operating mode.

Reprogramming the counter

Switch on the instrument and press the

key simultaneously.

to the defaults settings

●

All the programmed values will now revert to their defaults
settings.

5.1 Operating modes

The operating modes are described below.

Step preset

On reaching a preset value, the counter continues to count to the
next preset value. Preset values are always processed in the
sequence: preset value 1, preset value 2. Any values can be chosen.
External or manual resetting can be carried out at any time.

P1- Self-adjusting preset

Preset value P1 serves as a preliminary signal and functions as a
self-adjusting preset. The preliminary signal always switches to the
input value before the final signals is given. Any second preset value
can be chosen.