Ne215, Programming mode – Baumer NE215 User Manual

Page 20

Advertising
background image

20

NE215

Programming field 4

Line 43

Baud rate

0 * 4800 baud
1

2400 baud

2

1200 baud

3

600 baud

Line 44

Parity

0 * Even parity
1

Odd parity

2

No parity

Line 45

Address

* 0

1-99

Line 46

Stop bits

0 * 1 Stop bit
1

2 Stop bits

At the conclusion of these programming lines, a broken line will
appear in the display, signifying the competion of the fourth
programming segment.

To leave programming mode

Press the

key.

Counter now reverts to the operating mode.

Reprogramming the counter

Switch on the instrument and press the

key simultaneously.

to the defaults settings

All the programmed values will now revert to their defaults
settings.

5.1 Operating modes

The operating modes are described below.

Step preset

On reaching a preset value, the counter continues to count to the
next preset value. Preset values are always processed in the
sequence: preset value 1, preset value 2. Any values can be chosen.
External or manual resetting can be carried out at any time.

P1- Self-adjusting preset

Preset value P1 serves as a preliminary signal and functions as a
self-adjusting preset. The preliminary signal always switches to the
input value before the final signals is given. Any second preset value
can be chosen.

Programming mode