Ne215, Counter connect – Baumer NE215 User Manual

Page 9

Advertising
background image

9

NE215

3.4 Connecting the encoder supply

Connect the encoder supply at terminals 19 and 20.
Do not use the encoder supply to supply non-earthed inductive or
capacitive loads.

The encoder power supply is not short-circuit proof.

3.5 Interface connect

The serial interface is capable of executing the following functions:
– Data printout

Interface parameter are as follows:
– Data transmission rate (baud rate),
– Parity bit,
– Number of stop bits,
The interface parameters can be set in the programming
(lines 43, 44, 45 and 46).

The following interfaces can be connected to the counter:
– RS232

Interface characteristics

RS232 Transmission with the following characterisics:

– Asymmetric
– Two leads
– Point-to-Point connection - 1 transmitter and 1 receiver
– Max. data transmission distance: 30 m

Counter connect

Terminal

Voltage

Max.

Max. permissible

residual ripple

current

19

0V

20

+24 VDC

Depending on load

80 mA

+10 %/-50 %