Ne215, Programming mode – Baumer NE215 User Manual

Page 18

Advertising
background image

18

NE215

Programming segment 3
Programming segment 3 begins with programming line 21.
14 programming lines are displayed in sequence in these segments.

Default settings are always printed with * .

Line 21

Operating modes
0 * Step preset
1

P1 Self-adjusting preset

Line 23

Multiplier, secondary counter
1 * 1
2

2-99

Line 26

Frequency, secondary counter XB
0 * 10 kHz
1

25 Hz

2

15 Hz

Line 30

Reset secondary counter
0 * Autom. reset and external static
1

Autom. reset and external differential

2

External static

3

External differential

Line 31

Output time P1
00.00 * Data in Sec. (Tol. -0.01 s, range 00.02 -99.99 s)
00.25 0.25
99.99 Maximum puls time
LAtch Latch= continuous signal

Line 32

Output time P2
00.00 * Data in Sec. (Tol. -0.01 s, range 00.02 -99.99 s)
00.25 0.25
99.99 Maximum puls time
LAtch Latch= continuous signal

Line 33

Output time B1
00.00 * Data in Sec. (Tol. -0.01 s, range 00.02 -99.99 s)
00.25 0.25
99.99 Maximum puls time
LAtch Latch= continuous signal

Line 34

Accept presets P1, P2 and B1
0 * On reset
1

Effective immediately

Line 35

Adresses for function key
0 * No function
1

Any parameter selection

:
8

Programming mode

Advertising