NE215

Programming mode

Line 36

Secondary counter functions XB
0 * External
1

Internal

2

Tachometer

Line 37

Pulses per unit of measurement, as tachometer
1.00 * 1,00
0,01

- 9999.99

Line 38

Input of time measurement in seconds (s)
0 * Time base 1 s
1

Time base 2 s

2

Time base 3 s

3

Time base 6 s

4

Time base 10 s

5

Time base 20 s

6

Time base 30 s

7

Time base 60 s

The time base must be selected in accordance with the pulse
rate.

Examples

Line 40

Function input time meter
0 *

Operating hours with supply on/off

1

Operating hours on/off

Line 41

Code setting
0 * No code
1

-9999

At the conclusion of these programming lines, a broken line will
appear in the display, signifying the competion of the third
programming segment.

Pulses per rev.

Time base in seconde

60 pulses/rev

1 s

< 60

30 pulses/rev

2 s

to

to

1 pulses/rev

60 s