Ne215 operating mode 4 operating mode – Baumer NE215 User Manual

Page 11

Advertising
background image

11

NE215

Operating mode

4

Operating mode

The operation and use of the counter are described in this section.

As soon as the power supply has been switched on, the
counter is automatically set to the operating mode.

Operating mode

In the operating mode:
– the current main counter status can be read and reset;
– the preset values for the main and secondary counters can be

read;

– the current total can be read and reset;
– the current status of the secondary counter can be read and reset;
– the operating hours counter can be read.
All the parameters can be disabled in the programming mode.

Main counter status
The current counter status is displayed in the operating mode;
no keying is necessary.

To read

Readout running counter value.

Reset

Resetting must be enabled in the programming mode.

Press the

key.

Main counter preset value
Resetting must be enabled in the programming mode

To read

Press the

key.

Read preset value P1.

To change

Press the

key.

LED P1 flashes.

Press the

key.

Preset 1 is being deleted.
Input the preset value P1 via the numerical keypad.

Press the

key.

The change is completed.

If a key is not operated within 15 seconds, the preset value will
automatically be re-displayed in the operating mode.

Other changes

Press the

key.

The following values can also be changed.