Ne215 counter connect, 3counter connect – Baumer NE215 User Manual

Page 6

Advertising
background image

6

NE215

Counter connect

GND

RxD

TxD

RS232

26

25

24 23

22

21

RS485

T,

R

+

T,

R

-

1 Relay contact output P1

1 Relay contact output B1

1 Relay contact output P2

3

Counter connect

This chapter will explain how the contacts are assigned.
Under chapters 3.1 to 3.5 you will find actual tips and technical data
for the various connections.

The electrical inputs and outputs are assigned to two 12-pole plug-in
screw terminals, coded to prevent reversed polarity.

Assignment

Contact

Function

1

Not assigned

2

Supply voltage

3

Supply voltage

4

5
6

7
8
9

10
11
12

Signal input, track A

13

Signal input, track B

14

Reset XP

15

Time meter

16

Signal input, track B1

17

Reset B1

18

Coding input for input logic

19

Encoder supply 0 Volt

20

Encoder supply +24 Volt

21

Option RS485 T,R-

22

Option RS485 T,R+

23

Option RS232 TXD

24

-

25

Option RS232 RXD

26

Option RS232 GND

Litz contact only by means of connector sleeves with insulating
enclosures for reasons of shock protection according to VDE 0411
part 100. Do not otherwise assign contacts that have been left
unassigned ex factory. We recommend to screen all encoder
terminal leads and to ground the shield on one side. Shields on
both sides are recommended in case of RF interference or in case
of equipotential bonding over long distances. The encoder leads
should not be in the same phase winding as the MAINS supply and

the output contact leads.

max. 250 V

Terminal - Terminal

- Terminal

Output

B1

P2

P1

B

A

Count

+24V 0V

Sensor

supply

NPN Br

. 1

8-20

PNP Br

. 1

8-1

9

B1 reset

B1 counter

(Scaling on)*

XP reset

Supply

22

21 20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

h counter

* Models with scaling