Ne215 programming mode – Baumer NE215 User Manual

Page 17

Advertising
background image

17

NE215

Programming mode

Programming segment 2
In the second programming segment, the message STAT appears in
the display, signifying status selection.

●

appears in the display. The LED for the corresponding

operating parameter flashes.

Significance of status numbers

0

Full access for operator (read and alter parameters).

1

Restricted access for operator (read parameters only).

2

None access for operator (No altering, no reading of parameters).

To change status

Input the appropriate status number.

●

The changed status will automatically be stored when the next
programming line is selected.

Press the

key again.

●

The status of each individual operating parameter is called up in
sequence.

Line 1

XP - Main counter status

Line 2

P1 - Preset value 1

Line 3

P2 - Preset value 2

Line 4

∑

- Totalizer

Line 5

XB - Secondary counter status

Line 6

B1 - Secondary counter preset value

Line 7

- Time meter

●

At the conclusion of the first programming segment, a broken
line appears in the display.

The default operating parameter status is zero.