Ne215 programming mode – Baumer NE215 User Manual

Page 21

Advertising
background image

21

NE215

Programming mode

5.2 Counting modes for the main and totalizing counter

Up/down counting with two counting signals, phase-offset by
90 degrees
The counting direction is automatically identified from the leading/
lagging 90

o

phase offset.

The internal phase discriminator performs the necessary evaluation.

5.3 Output responses (Output Modes)

Signal output response is determined by the following:
– Programming of the preset value, output time, output logic and

output function;

– external resetting;
– external counting direction control.

The diagrams belows show the output signal responses.

Adding operating mode

Step preset with continuous signal, without automatic reset

Adding operating mode

Step preset with pulse signal, without automatic reset

Adding operating mode

Self-adjusting preset with pulse signal, without automatic reset

Input of the preset value P1 corresponds to the interval between the
preliminary signal and the final signal. This means that, if the final
signal (i.e. preset value P2) is changed, the preliminary signal is
automatically readjusted.

Track A

Track B

RESET

VW (P2)

VW (P1)

O (SC)

OUT P1

OUT P2

RESET

SC

VW (P1)

VW (P2)

OUT P1

OUT P2

RESET

VW (P2)

O

OUT 1

OUT 2

(SC)

VW (P1)

Tw

Tw