Locate the four 1

1

/

4

-in. drain coupling assemblies and

mounting screws (shipped in a bag taped to the basepan in the

supply fan section, located behind the access panel marked

FAN SECTION). The drain couplings are a 10-gage plate with

a 1

1

/

4

in. half coupling welded to the plate.

After final positioning of the unit, perform the following

procedure:

1. At each of the four secondary drain locations (marked

with labels on the unit base rail), position the drain cou-

pling assembly in the side of the base rail. Mark the

screw holes and the drain hole locations on the base rail.

2. Drill holes for drain outlet (use 1

3

/

8

-in. hole saw) and for

the mounting screws (use

3

/

16

-in. drill bit).

3. Install a drain coupling assembly using screws provided

at each secondary drain hole location.

4. Using field-supplied fittings and pipe sections, assemble

U-traps at each secondary drain fitting. See Fig. 24. Pro-

vide minimum size of ½-in. pipe for secondary drains.

Use a trap at least 4-in. deep for size 030-070 units and

7-in. deep for size 075-100 units.

5. Apply a bead of RTV or similar sealant around the drain

assemblies.

Consult local plumbing codes for direction on joining multi-

ple drain lines. Total size of any combined line does not need to

exceed nominal 2-in. size of primary drain connection.

Fill the U-traps at the secondary drain locations prior to unit

start-up. Also check the U-traps before each cooling season to

ensure the traps are filled and functioning properly.

3

2

A

B

4

1

NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.

48P2,P3,P4,P5 UNITS

WITH OPTIONAL RETURN FAN

SIZE

CORNER WEIGHTS (lb)

TOTAL

(lb)

A

B

1

2

3

4

in.

in.

Vertical Supply/Return
Horizontal Supply/Return
Low Heat

075

3470

3449

2693

2709

12,321

224

5

/

8

40

1

/

4

090

3327

3745

3097

2751

12,921

232

5

/

8

41

1

/

2

100

3302

3782

3127

2730

12,941

230

3

/

8

41

1

/

2

Vertical Supply/Return
Horizontal Supply/Return
High Heat

075

3543

3449

2693

2766

12,451

226

7

/

8

40

1

/

4

090

3377

3767

3115

2793

13,051

233

3

/

4

41

1

/

2

100

3370

3785

3130

2787

13,071

232

7

/

8

41

1

/

2

Vertical Supply/Return
Horizontal Supply/Return
Low Heat with Extended Chassis

075

3609

3618

2825

2818

12,871

236

1

/

4

40

1

/

4

090

3467

3906

3230

2867

13,471

244

1

/

4

41

1

/

2

100

3437

3948

3264

2842

13,491

241

3

/

4

41

1

/

2

Vertical Supply/Return
Horizontal Supply/Return
High Heat with Extended Chassis

075

3681

3620

2826

2874

13,001

238

1

/

2

40

1

/

4

090

3517

3928

3248

2908

13,601

245

3

/

8

41

1

/

2

100

3505

3951

3267

2898

13,621

244

1

/

4

41

1

/

2

Fig. 11 — Weight Distribution and Center of Gravity (cont)