Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 152

Advertising
background image

A-16

Installation and Troubleshooting Guide

DIAG-CMINOCAP

(T!--
[cmiTest]

CMI intended receiver ASIC
failed to get CMI capture flag

ASIC or mainboard
failure

Replace main-
board assembly

DIAG-CMISA1

(T!-!
[cmiTest]

An attempt to send a CMI mes-
sage from ASIC to ASIC failed

ASIC failure

Replace main-
board assembly

DIAG-CMNOBUF

(T!
[centralMemoryTest]

Port could not get any buffer

ASIC failure

Replace main-
board assembly

DIAG-DATA

(T!(5-(
[portLoopbackTest, crossPort-
Test]

Payload received by port did
not match payload transmitted

Mainboard, GBIC
module or fiber
cable failure

Replace main-
board assembly,
GBIC module or
fiber cable

DIAG-ERRSTAT

(T!!75-

-75

- - 7
[portLoopbackTest,
crossPortTest, spinSilk]

Port Error Statistics counter is
nonzero, meaning an error was
detected when receiving
frames.
One of the following status
errors occurred:



Enc_In: Encoding error,
inside frame



CRC_err: Cyclic redun-
dancy check on frame
failed



TruncFrm: Truncated
frame



FrmTooLong: Frame too
long



BadEOF: Bad end of file.



Enc_out: Encoding error,
outside frame



BadOrdSet: Bad symbol
on fiber-optic cable



DiscC3: Discarded Class 3
frames

ASIC, mainboard,
GBIC module or
fiber cable failure

Replace main-
board assembly,
GBIC module or
fiber cable

DIAG-INIT

(T!)5-)5- )
[portLoopbackTest, crossPort-
Test, spinSilk]

Port failed to go active in the
loopback mode requested

ASIC, mainboard,
GBIC module or
fiber cable failure

Replace main-
board assembly,
GBIC module or
fiber cable

DIAG-INTNIL

(T!-
[cmlTest]

ASIC failed to get a CMI error
(interrupt)

ASIC failure

Replace main-
board assembly