Troubleshooting, Diagnostic overview, Diagnostic error messages – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 99: Diagnostic overview -1, Diagnostic error messages -1

Advertising
background image

support.dell.com

Troubleshooting

5-1

       

    

This chapter discusses troubleshooting, diagnostic testing, and error messages,
including the following sections:



Diagnostic overview



Status and activity indicators



Diagnostic tests

Refer to the Dell PowerVault Systems Storage Area Network (SAN) Installation and
Troubleshooting Guide
for further troubleshooting information.

   %'')

The switch is designed for maintenance-free operation. When there is a suspected
failure, the switch has self-diagnostic capabilities to aid in isolating any equipment or
fabric failures.

The switch supports power-on self-tests (POSTs) and diagnostic tests. The diagnostic
tests determine the switch’s status and isolate problems.

Telnet commands are used to determine the switch’s status, error conditions, and
switch operating statistics.

&   6 

Error messages are available both by way of the switch’s front panel LCD display and
through a Telnet session. These messages are also stored in the system log and are
displayed when the errShow command is executed.

If you run the portStatsShow or the diagShow command prior to running a test on
the switch, errors may appear as a result of the normal synchronization process.
These errors should be addressed if the number of errors found increases when run-
ning the portStatsShow command again.

Where multiple probable cause and corrective actions are listed following an error
message, they are listed with the most probable first and the least probable last.

If any port fails during a diagnostic test, it is marked

;03 in the status display and is

ignored (not tried) until the system is rebooted.