Figure 4-2, Configure command submenus -8 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 64

Advertising
background image

4-8

Installation and Troubleshooting Guide

.

(   % !!'!

switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] yes
Domain: (1..239) [1]
BB credit: (1..16) [16]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
Data field size: (256..2112) [2112]
Non-SCSI Tachyon Mode: (0..1) [0]
Disable Device Probing: (0..1) [0]
Unicast-only Operation: (0..1) [0]
VC Encoded Address Mode: (0..1) [1]

Per-frame Route Priority: (0..1) [0]
Virtual Channel parameters (yes, y, no, n): [no] yes
VC Link Control: (0..1) [0]
VC Class 2: (2..5) [2]
VC Class 3: (2..5) [3]
VC Multicast: (6..7) [7]
VC Priority 2: (2..3) [2]
VC Priority 3: (2..3) [2]
VC Priority 4: (2..3) [2]
VC Priority 5: (2..3) [2]
VC Priority 6: (2..3) [3]
VC Priority 7: (2..3) [3]
Arbitrated Loop parameters (yes, y, no, n): [no] yes

Send FAN frames?: (0..1) [1]
System services (yes, y, no, n): [no] yes

rstatd (on, off): [off] on
rusersd (on, off): [off] on
No changes.

Disable Translative Mode: (0..1) [1]

Advertising
This manual is related to the following products: