Syslogdip, Tempshow, Syslogdip -31 – Dell PowerVault 56F (16P Fibre Channel Switch) User Manual

Page 87: Tempshow -31

Advertising
background image

support.dell.com

PowerVault 56F 16-Port Fibre Channel Switch Commands

4-31

 )%

The syslogdIp command sets or displays the switches system log daemon IP
address. The command syntax is

syslogdip <ip address>.

% #

The following example shows the tempShow command screen, which shows the
switch’s temperature as measured by five sensors on the system board.

Port state

The port state follows the GBIC type; the possible port states
include:



No_Card — No card present in this switch slot



No_Module — No GBIC module in this port



No_Light — The module is not receiving light



No_Sync — The module is receiving light but is out of
sync



In_Sync — The module is receiving light and is in sync



Laser_Flt — The module is signaling a laser fault (defec-
tive GBIC)



Port_Flt — The port has been marked faulty (defective
GBIC, cable, or device)



Diag_Flt — The port failed diagnostics (defective G_Port
or FL_Port card or system board)



Online — The port is up and running



Lock_Ref — The port locking to the reference signal



Testing — Running diagnostics

Comment field

The comment field follows the port state. The possible com-
ments include:



Disabled

The port is disabled



Loopback

The port is in loopback mode



E_Port

The WWN and switch name of the other

switch is shown, the use of this Inter Switch Link (ISL) is
shown (see FC_SW)



F_Port

The WWN of the N_Port is shown



G_Port

The port is online but is not yet an E_Port or

F_Port



L_Port

The port is connected to an arbitrated loop

( /    !!'' 

% 

   

Advertising
This manual is related to the following products: